蜜臀久久精品久久久久酒店,av电影在线观看你懂的,夜夜高潮夜夜爽国产伦精品,首页中文字幕中文字幕

產(chǎn)品列表PRODUCTS LIST

流量校準器Bios Defender 530-Low Flow

簡要描述:

Bios Defender 530 Standardized & Volumetric Flow
Primary Standard Air Flow Calibrators Air Flow Calibrators with DryCal? Technology The Bios Defender 530, with the ability to take both volumetric and standardized readings, is the latest addition to

更新時間:2025-10-29

發(fā)郵件給我們:554328895@qq.com

分享到: 1
在線留言
流量校準器Bios Defender 530-Low Flow

Bios Defender 530 Calibrator -- Coming January 2010

The Bios Defender 530, with the ability to take both volumetric and standardized readings, is the latest addition to the popular Defender 510 and 520 line of Bios DryCal primary flow calibrators. Automatic correction of readings for temperature and pressure, rather than merely recording of ambient conditions, is essential for many applications.

The Defender 530, like the other instruments in the line, provides users with a true primary flow calibrator for industrial hygiene, environmental and laboratory applications. The design offers low cost, light weight and ultra-compact size, incorporating the highly-regarded DryCal technology. It is small enough to fit easily into a slim briefcase for convenient transport.

Like all Bios calibrators, the Defender 530 is easy to use.  Turn it on. Connect it to a sampling pump. Start taking readings. It's as simple as that. Calibrations within a minute with no messy soap bubble solutions.

The Defender 510, 520 and 530 can take hands-free continuous readings while quickly and accuray setting the flow rate on air sampling pumps or other instruments. The Defender 510/520/530 calibrators connect to any PC and pre- and post-calibration data can be downloaded with the included Integrator 110 with the Optimizer Collect Light software. 

 

 



Bios Defender 530 Specifications


Size 5.5"H x 6"W x 3"D
140 mm x 150 mm x 75 mm
Weight 29 oz. / 820 g
Flow Ranges  
   DryCal Defender Low (L) Flow: 5 to 500 ccm
   DryCal  Defender Medium (M) Flow: 50 - 5,000 ccm 
   DryCal Defender High (H) Flow: 300 - 30,000 ccm
Accuracy  
   Volumetric ±1.0%
   Standardized ±1.2%
User-Selectable Measurement Units
   Volumetric Flow mL/min, L/min, cc/min, cf/min
   Standarized Flow smL/min, sL/min, scc/min, scf/min
   Pressure mmHg, PSI, kPa
   Temperature ºC, ºF
Readings  
   Approximate Time per Reading 1-15 seconds
   Reading Styles Single (manual), Continuous or Burst, with averaging function user-selectable from 1 to 100 measurements
Gas Compatibility Use with non-corrosive, non-condensing, non-combustible gases, less than 70% humidity
Flow Modes Suction or Pressure
Measurement Cell Style Integrated
Temperature & Pressure Sensors In the flow stream
Press: 3.5 mmHg (typical), 7.0 mm (max)
Temp: 0.8 °C (typical) 1.3 °C (max)
Battery System  
   AC Adapter/Charger 12 DC, >250 ma, 2.5 mm, center positive
   Battery 6V rechargeable, sealed lead-acid, 6-8 hours typical operation
   Battery Operational Time  (5 cycles/min), 3 hours backlight on, 8 hours backlight off
Pressure & Suction Fittings ¼” ID Hose Barb
Display Backlit graphical LCD
Storage Temperature 0-70 °C
Ambient Humidity 0-70% - non-condensing
Operating Pressure  (Absolute) 15 PSI
Warranty Instrument: 1 year, Battery: 6 months
Data Port
Serial RS-232 (for use with Optimizer Collect software)
Data Cable 1 meter (Defender Data Port to PC Serial Port)
Protective Case Soft side or Pelican cases available
Laboratory Accreditation Backed by ISO 17025 accreditation by NVLAP of NIST
Instrument Certification RoHS and CE Compliant

Bios Defender 500 Kits Include:  One flow cell, Bios Optimizer 110 PC Serial Cable, Software CD, AC Power Adapter/Charger, Plastic Leak Test Caps (2), NIST-Traceable Calibration Certificate and Mini-Manual.

Bios Integrator 110 and Optimizer Collect Software

The Defender 510/520 and the Defender 530 come standard with the Bios Integrator 110 and Optimizer Collect Light software for bullet-proof transfer of an ASCII text file of the flow data into an Excel® spread sheet with automatic recording and graphing of flow measurements.

The Optimizer Collect software helps to meet the needs of ISO, TQM, or occupational health and safety management systems by providing a secure audit trail for all pump calibrations, regardless of the pump type or manufacturer.

The basic Bios Optimizer Collect Light allows users to download data directly to a Microsoft Excel® preconfigured Spreadsheet.for easier collection, storage and record-keeping.

Enter flow rates from pumps or other flow source and calibrate the flow source. Data is recorded directly to a preconfigured Microsoft Excel® Spreadsheet.

 

 

 

 

 


Enter flow data from a flow meter and capture and compare the flow measurements from tje Bios DryCal precision calibrator into a preconfigured Microsoft Excel® Spreadsheet.
Optiimizer Collect light is upgradeable to a full version of Collect by purchasing an Activation code from Bios for automatic multi-point calibration of MFC/MFM using DryCal and Integrator 110.

The upgrade to the Bios Optimizer Collect full version allows the user to not only capture, but secure, organize, search and present data.  It stores the records in a small but secure SQL database. These records can also be easily opened in a variety of off-the-shelf database applications, including Microsoft Excel and Access. 

 

The Bios Defender - Overview

Accuracy

  • Proven percent of reading accuracy is supported by ISO 17025 accreditation by NVLAP of NIST
  • Integrated temperature sensors and pressure transducers placed directly in the flow stream for optimum standardized results.

Convenience

  •  Housed in a molded case with rubber handgrips for a better feel and a sleeker, more contemporary look
  •  Large illuminated flow cell viewing window
  •  Navigation menu and a large, illuminated graphical display with zoom feature
  •  Rated for extreme cold operation, down to -20 ºC
  •  RoHS (Restriction of Hazardous Substances) compliant for Europe
  •  Automatic Shutoff

Flexibility

  •  Choose between flow units
    • – Volumetric: mL/min, L/min, cc/min, or cf/min
    •   Standardized: smL/min, L/min, cc/min, scf/min
  •  Include up to one hundred readings in a group average
  •  Take individual readings, continuous hands-free readings, or set to read in time intervals anywhere from one minute to sixty minutes between readings
  •  Available in three models for application expansion. Use the
    • Bios Defender 510 to calibrate personal air samplers and other volumetric instruments;
    • Bios Defender 520 "three-in-one" to calibrate volumetric instruments, record ambient temperature and pressure conditions for the audit trail, or to calibrate devices that read in mass flow;
    • Bios Defender 530, for both volumetric flow readings or standarized readings, which correct for temperature and pressure, or to calibrate devices that read in mass flow,.

Software:

  • The Integrator 110 and Optimizer Collect Light software is bundled with the Defender with an integrated serial PC interface for easy transfer of flow data to a text file, with automatic recording and graphing of flow measurements.
  • The upgrade to the Bios Optimizer Collect Full version allows the user to not only capture, but secure, organize, search and present data. It stores the records in a small but secure SQL database. These records can also be easily opened in a variety of off-the-shelf database applications, including Microsoft Excel and Access.
 
国产亚洲av日韩精品熟女| 亚洲日韩精品av成人波多野| 真人做爰免费的视频| 日韩欧美视频午夜福利视频| 男人j进入女人j内部免费网站| 性色av无码久久一区二区三区| 欧美黄一级| 欧美色欧美亚日韩在线视频| 一本大道东京热无码一区| 快穿之菊爆男受np系统| 国产又色又爽又黄的| 国产xxnxx精品视频| 男男车车的车车网站w98免费| 亚洲精品粉嫩小泬18p| 精品艹99啊啊| 亚洲av不卡无码国产| 东北少妇露脸无套对白| 日本在线a免费视频不卡| a亚洲va欧美va国产综合| 久久久精品免费热线观看| 狠狠色综合激情丁香五月| 亚洲天堂午夜| yy111111少妇无码理论片| 99re国产熟女四区精品| 卧室征服朋友人妻| 日本高潮喷奶水在线播放| 深夜福利视频在线播放| 亚洲中文字幕在线观看| 后入内射欧美99二区视频| 99re热这里只有精品视频| 国产精品亚洲综合第一区| 久久久久999精品影院| 九九热精品免费| 男人干女人骚逼一区视频| 一级高清视频| 人妻无码一区二区视频| 精品人妻无码一区二区色欲产成人| 东京热无码人妻精品专区| 亚洲 欧美 动漫 少妇 自拍| 孕夫欲h嗯啊大肚| 婷婷欧美一区午夜91天堂|